For testing the permeability performance of diapers and sanitary napkins, such as absorption speed, rewet amount, and leakage amount.

GB/T 28004.1-2021,GB/T 28004.2-2021

1.Automatically performs functions such as liquid addition, constant pressure application, and timing during the test, while measuring absorption performance indicators of the sample, including pressurized absorption speed, rewet amount, and leakage amount.

2.Features touch screen control with a user-friendly Chinese/English menu interface for convenient operation.

3.Equipped with five testing stations, each capable of independent liquid addition volume and flow rate settings.

4.Includes five independent electrodes and five liquid addition pumps, allowing simultaneous measurement of different sample types, including adult and child products.

5.Fully automated testing, capable of automatic liquid addition, testing, and pressure application.

6.Utilizes a high-precision peristaltic pump to ensure accurate liquid delivery volume.

7.Electrodes are made of platinum, offering fast response and long-lasting durability.

8.Employs stepper motors and high-precision ball screw transmission for accurate stroke control.

9.Features automatic data processing, providing test averages, standard deviations, and coefficients of variation.

10.Configured with a high-precision balance that directly calculates leakage and rewet amounts after weighing.

11.The liquid tank is constructed from 316L stainless steel, with built-in heating elements and a level gauge for precise temperature and liquid level control.

12.Includes a built-in thermal printer for quick on-site printing of test results.

13.Professional computer analysis software enables two-way operation with a PC.

14.Performs automatic liquid addition and testing, eliminating the need for manual intervention.

15.Uses stainless steel weight blocks to provide constant pressure, effectively preventing pressure variations caused by sample absorption.

16.Equipped with a buzzer alert function.

1.Timing Device Precision: 0.01 s

2.Liquid Dispensing Device:

Dispensing volume deviation: ±2 mL

Dispensing flow rate: 200–800 mL/min

3.Liquid Dispensing Tank Capacity: 2 L

Dispensing volume for infant diapers: (40 ± 2) mL / (60 ± 2) mL / (80 ± 2) mL

Dispensing volume for infant diaper pads: (30 ± 2) mL / (40 ± 2) mL / (50 ± 2) mL

Dispensing volume for adult diapers: (100 ± 2) mL / (150 ± 2) mL

Dispensing volume for adult diaper pads: (70 ± 2) mL / (100 ± 2) mL

4.Dispensing Flow Rate:

For infants: (480 ± 10) mL/min

For adults: (720 ± 15) mL/min

5.Dispensing Pressure: (2.0 ± 0.2) kPa

6.Pressure Application: (4.0 ± 0.2) kPa

7.Standard Test Liquid Dispensing Module:

infants

W

(80±1)mm(M1)

(85±1)mm(M2)

(95±1)mm(M3)

L

(100±1)mm(M1)

(108±1)mm(M2)

(125±1)mm(M3)

adults

W

(70±1)mm(M1)

(95±1)mm(M2)

/

L

(170±1)mm(M1)

(170±1)mm(M2)

/

8.Standard Test Pressure Application Module:

infants

W

(80±1)mm(Y1)

(85±1)mm(Y2)

(95±1)mm(Y3)

L

(100±1)mm(Y1)

(108±1)mm(Y2)

(125±1)mm(Y3)

adults

W

(70±1)mm(Y1)

(95±1)mm(Y2)

/

L

(170±1)mm(Y1)

(170±1)mm(Y2)

/

9.Sample Holder Base:

infants

U-shaped sample holder base

W

(122±1)mm(B1)

(135±1)mm(B2)

(152±1)mm(B3)

L

(125±1)mm(B1)

(136±1)mm(B2)

(154±1)mm(B3)

adults

Arc-shaped sample holder base

319mm×200mm

10.Balance Precision: 0.01g, Capacity: 300g

11.Dimensions: 1720 × 760 × 830 mm

12.Weight: 290 kg

13.Power Supply: AC 220V,50 Hz,1000W